- Coleman saluspa error codes how to#
- Coleman saluspa error codes portable#
- Coleman saluspa error codes code#
If the error is still showing you follow these steps to stop the error.
Coleman saluspa error codes code#
The error code E96 which displays on your Intex hot Tub Control Panel that means your Spa is facing a system error. If you are facing an error code of E96 on your Intex Inflatable hot tub and want to troubleshoot it then you are at the right place.
Coleman saluspa error codes how to#
Troubleshoot Intex Pure Spa hot tub error code e90 How to Solve Intex Purespa Hot Tub Error Code E96 Turn on the control unit and activate the filtration to make sure there is water flowing through. Remove the filter cartridge assembly from the spa tub. The filter cartridge is clean and properly installed.Water is filled to the recommended level.If you don’t want to see again E90 Error code on your Intex Pure Spa Hot tub make sure these 2 things: Make sure the spa water is clean and sanitized.If there is debris inside, unscrew the spa inlet/outlet grid with a screwdriver. If E90 persists, check and ensure there is no debris inside the spa tub inlet and outlet grids.Clean the filter cartridge of the hot tub or replace it with a new one.For solving this problem all you have to do is following these steps: Check the attached troubleshooting Manual. If you getting an error code of E90 on your Intex Inflatable hot tub control panel it means no water is flowing through the system. What does error code e90 mean and how to solve it on Intex pure spa hot tub? So, the answer is here. 4 Other Intex Hot Tub Errors Codes and Their Solutions.3 Intex Hot Tub LED error Codes Chart With Troubleshooting.2 How to Solve Intex Purespa Hot Tub Error Code E96.If you require any further assistance, please contact Customer Service. and / or the water in the Filter Bowl is not hot then the PCU will need to be replaced. If the PCU shows E3 right away and the reading you see with your thermometer is below 113 F. RESET the GFCI and check the Temperature reading on the PCU display. Use a thermometer to check the temperature of the water sitting in the Filter Bowl. Cap the Intake and Discharge Ports in the Hot Tub and remove the Filter Bowl Lid. If the E3 Error still appears the next step is to determine if the sensor is reading correctly. You will need to unplug the GFCI, turn the PCU over and insert a thin 4" rod into the hole marked "Reset". it will cause the E3 and the High Limit Breaker to trip. If the water temperature added to the Hot Tub and PCU was over 116 F. If this is the cause then drain the hot water and add cold water enough to lower the temperature below 104 F.
Filling the Hot Tub directly from the Household Hot Water system could potentially reach this temperature. This will cause Faults and Performance issues with the PCU.Īnother possible cause is the temperature of the water in the Hot Tub has reached 113 F. The Pipe should be straight and not kinked or collapsed.ĭo Not Block or Restrict the Flow of the Intake or Discharge Ports located inside the Hot Tub. Check the Piping from the Discharge Port on the PCU to the Discharge Port on the Hot Tub, make sure it is straight and not kinked.īe sure the Cover Cap has been removed and check the Discharge Port for obstructions in the openings.Ĭheck the Piping from the Heater Discharge Port to the Hot Tub. Check the Discharge Port in the Hot Tub for obstructions in the openings and make sure the Clear Cap has been removed. This will reset the PCU, if the error code returns then you will need to follow the corrective steps for that code.Ī possible cause can be a restriction in the flow from the Discharge of the PCU. Anytime an error code appears first perform the PCU RESET - Plug in the GFCI - then Press the TEST BUTTON on the GFCI - wait 5 seconds -then press the RESET BUTTON. E3 will disable all functions and requires the PCU to be Reset (see solution) to clear once the temperature is within safe use range.ĭue to the sensitive nature of the sensors and control electronics it is possible that the error code was triggered by a surge in the supply power, a momentary loss of supply power or even the effect of lightning. 45 C.) within the PCU before the water has passed through the Heater. The E3 Error indicates a condition where the Temperature Sensor has sensed a high temperature (Greater than 113 F. Modified on: Thu, 14 Mar, 2019 at 9:39 AM
Coleman saluspa error codes portable#
Solution home Service Solutions Portable Spas PCU E3 Error Code